Profibus DP 61/176
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
SLK operation
Check the actual link state until the value CONNECTED appears (2). A new MDT has
now arrived. The controller reads the MDT status (4). When the MDT status does not
indicate an error, the user data can now be read starting with MDT address 0x0110.
Once this data has been evaluated and the workpiece processed, the result of
the processing is written to the MDT (6). Communication with the MDT is then
terminated.
No. Command-oriented data
exchange
CMD Data0 Data1 Data2 Data3 Data4 Data5 Data6
2 Wait until actual link state is CONNECTED. Read value through event-oriented data channel
4 Read MDT status and
check if error bits are
present
0x05 0x00 0x02 0x00 0x00 0x00 0x01
5 Read data from MDT,
e.g., 32 bytes as of ad-
dress 0x0110
0x05 0x00 0x00 0x01 0x10 0x00 0x20
6 Write data to MDT, e.g.,
60 bytes as of address
0x0100
0x06 0x00 0x00 0x01 0x00 0x00 0x3C data...
8 Close MDT
(RECONNECT)
0x06 0x00 0x03 0x00 0x01 0x00 0x01 0x03
9 Wait until actual link state is CONNECTING. Read value through event-oriented data channel
PROOF COPY 1 | 20.05.2014 | FOR INTERNAL USE ONLY
ENGLISH