Stage 2: Once processing is complete and the measurement data is available, the
parameters for pretransmit are set (e.g., 80 bytes as of MDT address 0x01C0) and
configured as a single transmit (see Chapter 6.4.2 “Pretransmit”). By this time,
the workpiece pallet has lowered. The SLK switches to CONNECTING and the MDT
immediately signs on and executes the pretransmit.
No. Command-oriented data
exchange
CMD Data0 Data1 Data2 Data3 Data4 Data5 Data6
1 Delete pretransmit data
from last MDT
0x08 0x04
2 Begin setting pretrans-
mit parameters
0x08 0x00
3 Set parameters for
80-byte measurement
data block as
pretransmit
0x07 0x00 0x00 0x01 0xC0 0x00 0x50 Mea-
sure-
ment
data
4 Finish setting pretrans-
mit parameters
0x08 0x01
5 Activate “single trans-
mit”
0x08 0x02
6 Wait until lift positioning unit in lower position
7 Make SLK ready to
receive (CONNECT)
0x06 0x00 0x03 0x00 0x01 0x00 0x01 0x01
8 Wait until event counter in event-oriented data channel increases by 1. At this time, the
measurement data is written to the MDT and the link is DISCONNECTED (auto reconnect is
still active)
9 Make the SLK ready to
receive the next work-
piece pallet only once
the current workpiece
pallet is gone
0x06 0x00 0x03 0x00 0x01 0x00 0x01 0x01