70/176 Interbus
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
Object
index
Communication
object
Description Subindexes Format
5FF7 Configure
pretransmit
Begin or finish setting pretransmit param-
eters.
Start “single transmit” (ST) or “multiple
transmit” (MT).
Delete all parameterized data areas. Stop
pretransmit
Subindex 0:
0: Begin setting parameters
1: Finish setting parameters
2: Start ST
3: Start MT
4: Delete parameters
5: Stop pretransmit
2 bytes
Subindexes of objects that should transmit user data to the SLK have to be completely filled with data. The number
of bytes that should be entered in the system can be lower and has to be entered in each “No. bytes” subindex.
Unassigned bytes in the process data channel transfer the value 0.
PROOF COPY 1 | 20.05.2014 | FOR INTERNAL USE ONLY