System Reporting Information
Arm/Disarm Reporting Options
Item Location Option Default New
Arm / Disarm
Reporting Options
0403 0 = No Arm / Disarm Reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
3 = Report to Receiver 3
4 = Report to Receiver 4
5 = Report to Receiver 1,2,3,4
6 = Report to Receiver 1 (2,3,4 backup)
7 = Report to Receiver 1 (2 backup) and
Receiver 3 (4 backup)
1
Location 403 is set by default to report only to Receiver 1.
Codepad Reporting Options
Item Location Option Default New
Codepad Reporting
Options
0411 0 = No Codepad Alarm Reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
3 = Report to Receiver 3
4 = Report to Receiver 4
5 = Report to Receiver 1,2,3,4
6 = Report to Receiver 1 (2,3,4 backup)
7 = Report to Receiver 1 (2 backup) and
Receiver 3 (4 backup)
1
Location 411 is set by default to report only to Receiver 1.
Access Denied
Item Location Option Default New
Code retry limit 0424 0 = Unlimited
1 – 15 = Error code attempts
6
An Access Denied Report (Contact ID Event Code 461) is sent to the base station receiver
when the number of incorrect code attempts equals the number programmed in Location 424.
An Access Denied Alarm is audible, but you can program the alarm as silent by selecting
Option 8 in Location 493 (refer to System Options 2, page 139).
Notice!
Restore Reports for this event are not transmitted.
Code Retries
The Code Retries feature restricts the number of times an invalid User Code can be entered in
an attempt to operate the system. Location 424 sets the number of incorrect code attempts
that causes an alarm. When the number of incorrect code attempts equals the number
programmed in this location, the system performs these actions:
15
15.1
15.2
15.3
Control Panel System Reporting Information | en 111
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)