Output Event Types, page 123
Auto Arming Time
Item Location Option Default New
Hour of the day (tens digit) 0482 0
Hour of the day (units digit) 0483 0
Minute of the day (tens digit) 0484 0
Minute of the day (units digit) 0485 0
These locations specify the time of day the system automatically arms itself in AWAY Mode.
Set this time in 24-hour format (for example, program 10:30 PM as 2230). If you want the
system to arm in STAY Mode 1, select Option 4 in Location 496.
If forced arming is disabled for any zone, the automatic arming feature operates regardless of
whether any zones are unsealed.
User Code 997 is reported when this feature is used. For partitioned control panels, both
areas are automatically armed in AWAY Mode at the same time each day.
See also
Consumer Options 1, page 141
Zone Options 2, page 101
Auto Disarming Time
Item Location Option Default New
Hour of the day (tens digit) 0486 0
Hour of the day (units digit) 0487 0
Minute of the day (tens digit) 0488 0
Minute of the day (units digit) 0489 0
These locations specify the time of day the system automatically disarms itself. Set this time
in 24-hour format (for example, program 10:30 PM as 2230).
User Code 997 is reported when this feature is used. For partitioned control panels, both
areas are automatically disarmed at the same time each day.
Kiss-Off Wait Time
Item Location Option Default New
Increments of 500 ms (500 ms to 8
sec.)
0490 3
This location sets the time the control panel waits for acknowledgment before resending a
report. This timer applies only to Contact ID and SIA Format.
Speaker Beep Volume
Item Location Option Default New
Speaker Beep Volume 0491 0 = No Beeps
15 = Loudest Beeps
13
This location allows you to adjust the speaker volume for remote radio operation.
17.12
17.13
17.14
17.15
Control Panel System Event Timers | en 137
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)

Related product manuals