Primary Telephone Number for Receivers
Item Location Option Default New
Phone Number 1 - Receiver 1 0000 - 0015 15 = Telephone termination 15
Phone Number 1 – Receiver 2 0040 - 0055 15 = Telephone termination 15
Phone Number 1 – Receiver 3 1417 - 1432 15 = Telephone termination 15
Phone Number 1 – Receiver 4 1457 - 1472 15 = Telephone termination 15
When the control panel transmits a report, the panel dials the Primary Telephone Number to
contact the monitoring station, for example. If the call is successful, the relevant information
is transmitted and the communicator returns to Standby Mode.
If unsuccessful, the communicator attempts two more calls using the Primary Telephone
Number for Receiver 1. If these calls are unsuccessful, the communication module calls the
Secondary Telephone Number for Receiver 1 up to three times. If the dialing sequence is still
unsuccessful, the control panel repeats this sequence by dialing the Primary and Secondary
Telephone Numbers for Receiver 2 (if they are programmed).
If the first six attempts are unsuccessful and no telephone numbers for Receiver 2 are
programmed, this procedure is repeated every 10 min continuously till the report is
transmitted successfully.
Contact your monitoring station for the correct telephone numbers before you program these
locations. With a text codepad, go to menu 711 First Phone Number to program the primary
telephone numbers.
Secondary Telephone Number for Receivers
Item Location Option Default New
Phone Number 2 – Receiver 1 0016 - 0031 15 = Telephone termination 15
Phone Number 2 – Receiver 2 0056 – 0071 15 = Telephone termination 15
Phone Number 2 – Receiver 3 1433 – 1448 15 = Telephone termination 15
Phone Number 2 – Receiver 4 1473 – 1488 15 = Telephone termination 15
For programming information, refer to Primary Telephone Number for Receivers, page 69. With a
text codepad, you go to menu 712 Second Phone Number to program the secondary
telephone numbers.
Transmission Format for Receivers
Item Location Option Default New
Transmission Format – Receiver 1 0033 0 = Not used
1 = Contact ID
4 = Domestic
5 = Conettix IP
6 = SIA Fast
7 = SIA Slow
8 = CSVIP
9 = Email
1
Transmission Format – Receiver 2 0073 1
Transmission Format – Receiver 3 1450 1
Transmission Format – Receiver 4 1490 1
11.1
11.2
11.3
Control Panel Communication Information | en 69
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)