Reset Latching Outputs
Holding down [7] until two beeps sound resets any output that is programmed to remain on
after it is activated. The output must be programmed with a latching polarity.
See also
Output Polarity, page 130
Change the Codepad Buzzer Tone
Holding down [8] continuously changes the tone of the buzzer in the remote codepad. There
are 50 different tones from 1500 Hz to 5000 Hz. In an installation with multiple codepads, you
can set a different tone for each codepad.
To change the buzzer tone:
1. Press and hold [8] continuously. The tone of the buzzer increases in pitch.
2. Release [8] button when you hear the desired tone.
Notice!
Every time the system is powered down, you must reset each codepad to its individual tone
using this function.
On partitioned control panels, this hold-down function also indicates the area to which the
codepad belongs.
To determine the area to which the codepad belongs:
1. Press and hold [8] until two beeps sound. A zone indicator lights to show the area to
which the codepad belongs.
Zone 1 = Area 1 codepad
Zone 2 = Area 2 codepad
Zone1,2 = Common Codepad for both Area1 and Area2
If no zone indicator lights, the codepad is set up incorrectly or an incorrect codepad
is used.
2. Press [AWAY] to exit from this mode.
Send Test Report
Holding down [9] until two beeps sound transmits a Test Report (Contact ID Event Code 602)
to test the reporting capabilities of the system without activating the sirens.
7.4.10
7.4.11
7.4.12
58 en | System Functions Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)

Related product manuals