Notice!
If the system is disarmed when an alarm occurs, only an Arm Report is sent the next time the
system is armed.
A User Code with a priority set to Always Send Arm/Disarm Reports overrides this feature
(Arm/Disarm Reports are always sent for that User Code).
2 – STAY Mode Arm/Disarm Reports Enable
Select this option if Arm/Disarm Reports are required when the system is armed in STAY Mode
1 or STAY Mode 2.
If this option is selected, a Partial Arm Report is sent when the system is armed in STAY Mode
1 or STAY Mode 2.
4 – Delay Siren until Transmission Complete
If this option is selected, horn speaker, bell, and strobe outputs are not activated until after
the control panel sends the message and the base station receiver sends a kiss-off back to the
control panel. If multiple messages are transmitted, the sirens are activated after the last kiss-
off is sent.
If a Codepad Panic, Codepad Fire, or Codepad Medical Alarm is activated, horn speaker, bell,
and strobe outputs operate immediately.
8 – Extend Time to Wait for Handshake from 30 to 60 Sec
By default, the control panel waits approximately 30 sec for receipt of a valid handshake tone
after it dials the monitoring station. The handshake tone indicates to the control panel that it
reached the monitoring station and can now transmit its messages. Selecting this option
extends this wait time from 30 sec to 60 sec.
Communication Options 3
Item Location Option Default New
Communication Options
3
0179 1 = Set DTMF dialing pluses to 1 digit/sec
2 = Lockout telephone line fail alarm
4 = Reserved
8 = Reserved
2
1 – Set DTMF Dialing Pulses to 1 Digit/Sec
If this option is not selected, the DTMF dialing format dials at 5 digits per sec (that is, 100 ms
tone, 100 ms pause, 100 ms tone, 100 ms pause).
If this option is selected, the DTMF dialing format dials at the rate of 1 digit per sec (that is,
500 ms tone, 500 ms pause).
2 – Lockout Telephone Line Fail Alarm
Selecting this option allows an audible alarm only once per arming cycle when the control
panel detects the telephone line is cut or disconnected. This option does not follow the
Swinger Shutdown Count for Siren, in which you can program the number of times a zone can
sound an alarm during an arming cycle. Use Location 176 to program the telephone line fault
options, refer to Telephone Line Fail Options, page 76.
11.19
78 en | Communication Information Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)

Related product manuals