1
Introduction 9
1.1 About documentation 9
1.2 Bosch Security Systems, Inc. product manufacturing dates 9
2
System Overview 11
2.1 Product Matrix 11
2.2 Configuration and Parts 11
2.2.1 Control panel capacities 11
2.2.2 Parts list 12
2.2.3 Order separately 12
3
Installation workflow 13
4
Accessories 14
4.1 Codepads 14
4.1.1 Installer Menu 16
4.2 WE800EV2 receiver 18
4.3 HCT-4 keyfob 19
4.4 RADION receiver B810 19
4.5 RADION keyfobs 19
4.6 RADION repeater 20
4.7 RADION detectors 20
4.8 B308 Octo-output Module 20
4.9 B426/B426-M Conettix Ethernet Communication Modules 21
4.10 B450/B450-M Conettix Plug-in Communicator Interfaces 21
4.11 A-Link Plus Software 22
4.12 Remote Security Control 23
4.13 Remote Security Control Plus 23
4.14 Keyswitches 23
4.15 TF008 Plug Pack (TF008-B) 24
4.15.1 Install the transformer 24
4.16 DLA 24
5
Configuration 25
5.1 Installer Commands 25
5.1.1 Command 958 - Exit from Installer's Programming Mode without saving changes 25
5.1.2 Command 959 - Test IUI-SOL-ADAPTER 25
5.1.3 Command 960 - Save and exit from Installer's Programming Mode 26
5.1.4 Command 961 - Reset the Control Panel to Factory Default Settings 26
5.1.5 Command 962 - Copy the Control Panel Memory to IUI-SOL-ADAPTER 26
5.1.6 Command 963 - Copy IUI-SOL-ADAPTER data to the Control Panel 27
5.1.7 Command 965 - Set up Domestic Dialing Format 27
5.1.8 Command 966 - Enable/Disable the Automatic Stepping of Locations 28
5.1.9 Command 999 - Display the Control Panel Firmware Version Number 28
5.2 Disable Factory Defaults 29
6
System Operations 31
6.1 Arming the system in AWAY Mode 31
6.2 Disarming the system from AWAY Mode 31
6.3 Arming the System in STAY Mode 1 32
6.4 Disarming the system from STAY Mode 1 33
6.5 Arming the system from STAY Mode 2 33
Control Panel Table of Contents | en 3
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)