Solution 6000
24 Bosch Security Systems 12/14 BLCC610U
User Guide
3. Use the [] and [] keys to select the zone that you
want to set for chime, then press [OK]. Alternatively,
you can enter the zone number that you want to set
for chime, then press [OK].
If the zone is not programmed for chime, the keypad
will prompt:
Zone 1 Name Zn1
Zone Chime is OFF,
To turn ON, Press ON.
To Go Back Press OK
If the zone is programmed for chime, the keypad
will prompt:
Zone 1 Name Zn1
Zone Chime is ON.
To turn OFF, Press OFF.
To Go Back Press OK
4. Press [ON] or [OFF] to toggle the zone to be
monitored when chime mode is turned on.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Inputs > Commands >
Set Part 2 Zones
MENU 3-0-4
This menu allows you to program which zones are to be
monitored when an area has been turned Part 2 On.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [0] + [4].
A list of areas will display on the keypad.
2. Use the [] and [] keys to select the area that you
want to program zones for Part 2 On, then press
[OK]. Alternatively, you can enter the area number
that you want to program Part 2 On zones, then
press [OK].
The keypad will list all zones that can be
programmed for Part 2 On. A displayed on the
right side of the zone name indicates that the zone
is already bypassed.
Zn1 Zone 1 Name
Zn2 Zone 2 Name
Zn3 Zone 3 Name
Press
 OK or MENU
3. Use the [] and [] keys to select the zone that you
want to set for Part 2, then press [OK]. Alternatively,
you can enter the zone number that you want to set
for Part 2, then press [OK].
If the zone is not programmed for Part 2, the keypad
will prompt:
Zone 1 Name Zn1
Is not armed in Part2.
To Enable, Press ON.
To Go Back Press OK
If the zone is programmed for Part 2, the keypad will
prompt:
Zone 1 Name Zn1
Is armed in Part2.
To remove, Press OFF.
To Go Back Press OK
4. Press [ON] to monitor the zone when the area is
turned Part 2 On, or press [OFF] so that you do not
monitor the zone when the area is turned Part 2 On.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Inputs > Commands >
Smoke Sensor Reset
MENU 3-0-5
This menu allows you to reset smoke sensors.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [0] + [5].
A list of dierent areas will display on the keypad.
2. Use the [] and [] keys to select the area that you
want to reset the smoke detectors, then press [OK]
to select. Alternatively, you can enter the area
number, then press [OK].
The keypad will display the following:
Smoke Detector reset in
progress. Please wait
3. The keypad will automatically return to the menu
when all smoke detectors in the area has been reset.
Inputs > Zone Properties >
Zone Name
MENU 3-1-0
This menu allows you to program up to 20 characters for
the name of each zone.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [1] + [0].
A list of dierent zones will display on the keypad.
2. Use the [] and [] keys to select the zone name
that you want to change, then press [OK] to select.
Alternatively, you can enter the zone number, then
press [OK].
The keypad will display the following:

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C