EasyManuals Logo

Bosch SOLUTION 6000 User Manual

Bosch SOLUTION 6000
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Solution 6000
42 Bosch Security Systems 12/14 BLCC610U
User Guide
The keypad will scroll all zones that you can test.
To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
To test zone Zn2
open then close
Zone 1 Name
Press OK or MENU
3. Open and close each zone that needs to be tested.
A zone that has been successfully tested will no
longer scroll on the keypad display.
When all zones have been tested, the keypad will
display:
All zones have been
successfully tested
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
System > System Testing >
Battery Test
MENU 7-9-1
This menu allows you to manually test the systems back
up battery. The system will automatically test the battery
every four hours and every time the system is armed.
The battery test can take up to two minutes to complete
and the keypad will display the voltage of the battery
during the test.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [7] + [9] + [1].
The keypad will display current voltage whilst under
test:
Battery test in progress.
Please wait..
Voltage = 13.4V
To Go Back Press OK
If the battery has passed the test, the keypad will
display:
Battery Test Passed
Press OK To Continue
To Go Back Press OK
If the battery has failed the test, the keypad will
display:
Battery Test Failed
Please Call For Service
To Go Back Press OK
2. Press [OK] to exit.

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C

Related product manuals