Page #31 background imageLoading...
Page #31 background image
31Bosch Security Systems 12/14 BLCC610U
Solution 6000 User Guide
call can choose whether the message is also sent to other
numbers in the destination 1 list or not.
When reporting in domestic format, the call must be
acknowledged by the user who answers the incoming call.
If the user fails to acknowledge the call, the system will call
the next number in the list until the maximum number of
call attempts are reached.
To acknowledge the call, the user needs to press the [#] key
on their telephone.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [1] + [1].
If the control panel is not programmed to report
using one of the self monitoring formats, the
keypad will display the following:
Reporting format does
not allow user changes.
Contact installer for
further information
If the control panel has been congured to report
via a self monitoring format, the keypad will display
information for telephone number 1.
Phone 1= 0453287306
Phone 2=
Phone 3=
Press
 OK or MENU
2. Use the [] and [] keys to select the phone number
to add or change, then press [OK] to select.
The keypad will display the following:
Destination 1 Phone 1
0453287306_
Press
 0-9 OK to SAVE
3. Use the [] and [] keys to scroll the cursor left and
right across the phone number. Use the [] and []
keys to change the individual digit in the number or
press the [OFF] key to clear the whole number and
then enter the new number using the 0-9 keys.
4. Press [OK] to save and exit, or press [MENU] to
cancel.
Comms > Telephone Numbers >
Destination 2
MENU 5-1-2
This menu allows up to 5 phone numbers to be
programmed when one of the self monitoring formats
have been congured by your installer. See MENU 5-1-1 for
more information.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [1] + [2].
If the control panel is not programmed to report
using one of the self monitoring formats, the
keypad will display the following:
Reporting format does
not allow user changes.
Contact installer for
further information
If the control panel has been congured to report
via a self monitoring format, the keypad will display
information for telephone number 1.
Phone 1= 0453287306
Phone 2=
Phone 3=
Press
 OK or MENU
2. Use the [] and [] keys to select the phone number
to add or change, then press [OK] to select.
The keypad will display the following:
Destination 2 Phone 1
0453287306_
Press
 0-9 OK to SAVE
3. Use the [] and [] keys to scroll the cursor left and
right across the phone number. Use the [] and []
keys to change the individual digit in the number or
press the [OFF] key to clear the whole number and
then enter the new number using the 0-9 keys.
4. Press [OK] to save and exit, or press [MENU] to
cancel.
Comms > Telephone Numbers >
Call Forward On
MENU 5-1-6
When you leave your premises, you no longer need to
remember to manually activate the Call Forward On feature
via the telephone. These addresses allow you to program
the Call Forward On sequence that the control panel will
automatically use to divert your phone when you turn Area
1 ‘On.
In Australia, a typical sequence of activating the Call-
Forward On – After Time (All Calls) is described below:
i
Note
For other countries please substitute the appropriate
commands after consultation with your telephone
company.
*61 (To turn Call Forward On – After Time).
Telephone number that you want calls to go to (e.g.
0416123456).
*5# (End of Call Forward sequence after 5 seconds).

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C