EasyManuals Logo

Bosch SOLUTION 6000 User Manual

Bosch SOLUTION 6000
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
29Bosch Security Systems 12/14 BLCC610U
Solution 6000 User Guide
The keypad will display the following during the
internal siren test.
Internal Audible Testing
Press any key to abort
Press OK or MENU
When the test is complete, the keypad will display
the following:
Testing Complete. Press
OK to continue
Press OK or MENU
3. Press [OK] to exit.
Outputs > Output Testing >
Strobe Test
MENU 4-9-2
This menu allows you to test the external strobe light.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [4] + [9] + [2].
If the system has multiple areas, the keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press
 OK or MENU
2. Use the [] and [] keys to select the area that
you want to test the strobe in, then press [OK].
Alternatively, you can enter the area number, then
press [OK].
The keypad will display the following during the
strobe test.
Strobe Activated. Will
Reset on exit
Press OK or MENU
Check and verify that the strobe light is on.
3. Press [OK] to exit.
Outputs > Output Testing >
Fire Siren Test
MENU 4-9-3
This menu allows you to test any sirens programmed as re
which have been connected by your installer. The test will
last for 5 seconds.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [4] + [9] + [3].
If the system has multiple areas, the keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press
 OK or MENU
2. Use the [] and [] keys to select the area that
you want to test the re sirens in, then press [OK].
Alternatively, you can enter the area number, then
press [OK].
The keypad will display the following during the re
siren test.
Fire Audible Testing
Press any key to abort
Press OK or MENU
When the test is complete, the keypad will display
the following:
Testing Complete. Press
OK to continue
Press OK or MENU
3. Press [OK] to exit.
Communication / Reporting
Programming options in this section relate to how you
alarm system will communicate alarm information.
Your installer will advise you on the exact makeup and
conguration of your system.
Comms > Commands >
Call/Answer RAS
MENU 5-0-1
This menu allows you to initiate a modem call to the
installers o-site computer for programming changes or
updates. Your installer may request that you enter this
command so that they can remotely service and congure
your system. You should not enter this command unless
requested to do so.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [0] + [1].
Comms > Commands >
Call Forward On/O
MENU 5-0-2
This menu allows you to turn on and o the call forward
feature. When you turn on call forwarding, the control
panel will automatically activate and de-activate the call
forward on and call forward o sequence accordingly
when you turn Area 1 All On and o (arm and disarm).

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C