Page 14 - Programming Manual 24805480/14-11-2012 319F92C ver. 1.2 -The data and information in this manual may be changed at any time with no obligation on BRAHMS’s part to notify anyone of this.
ENGLISH
ISTANTANEOUS 001
NEVER
+
-
Instantaneous: (Default:
NEVER
)
A
Parameter viewable only if the input is a delayed one.
For managing the delayed input as instantaneous if partialised (that is, if associated
to several areas and not all of them are switched on).
NEVER
Standard setting, the input is always delayed.
Example: overhead garage door.
IF PARTIAL. ON
The input is delayed if all of the associated areas are
switched on and is delayed if partialised (at least one area
switched off and one switched on).
Example: this parameter is set when it is necessary for the door to
be delayed-type when the User is not at home, and is instant when at
home (partialised system).
Area 1: Day time zone.
Area 2: Night time zone.
Area 3: perimetral.
Scenario 1: Going out; Areas
###
.
Scenario 2: Going to bed; Areas
#-#
.
Front door entrance: Instantaneous
DELAYED 1
; Type
IF PARTIAL. ON
;
And / or areas:
INS. IF AREAS OR
; Areas
-##
.
Balancing: (Default:
SINGLE BAL
)
F
S
A
NORM.CLS
Input normally closed.
NORM.OPN
Input normally open.
SINGLE BAL
Single balanced input.
DOUBLE BAL.
Double balanced input.
BALANCING 001
SINGLE BAL
+
-
Protection
Protection
Alarm
(NC)
4,7 kohm
Protection
Alarm
(NC)
Tamper (NC)
Protection
4,7 kohm

Questions and Answers: