CAP. 3 - SAFETY CONDITIONS 12 / 77 ENGLISH
M
ULTIGAS 8500 PLUS
STOP FOR LONG PERIOD: Store the equipment in a safe place, disconnected from the mains,
away from excessive temperatures, humidity and the risk of damaging impact.
Contact the Technical Service to run a safety shutdown of the equipment, and if scrapping the
unit, to drain and recycle the R134a or R1234yf gas as required by local legislation.
To resume operation, repeat the installation (there is no need to register the unit anew with
www.brainbee.com) and run the commissioning trials and regular operational checks as required
by local legislation.
TRANSPORT: If the tool has to be transported, you have to screw the safety screw for the tool
scale fixation. The safety device for transport is on the back of the tool and it consists of a bolt
with wing-nut. Commissioning: Slacken the wing-nut, unscrew the screw for about 4 mm. and fix
it again with the wing-nut. Transport: slacken the wing-nut, screw the screw by hand and then fix
it again with the wing-nut. For the transport of the R134a or R1234yf refrigerant, specific
regulations are in force in every country. Therefore, refer to your reseller or your authorised
service centre for information.