38 67XXU USB/Serial Scale Service Manual
PRIM.Ut kg lb Primary unit Select the primary unit from kg or lb.
The second unit is lb if kg is
selected as the primary unit.
*The calibration standard weight
must be in the primary unit!
lb
SECD.N 100-25000 Second scale full scale
value
The division number under second
unit. The maximum is
1.25*(PRIM.N).
*If (REGUL)≠none, the max is
10,000
NOTE: Secondary division has to
match the primary division.
10.DSP NO NO Display weight at 10
times division number
under primary unit
*If (REGUL)= none this parameter
will not be available.
When yes is selected, some
menus will not be active.
YES
MOTON 1-255 4 Motion window 1-255 = ±0.25d *(1-255)
*If (REGUL)=none, the max is 12
OVER.D 0-100 0 Overload display
limitation
0=FS+9d
1-100=101%FS -200%FS.
*If (REGUL)=none, the max is 10
UNITS KG yes yes UNITS key YES = enable this unit
No = disable this unit
In trade applications, lb:oz is not
allowed
no
lb yes yes
no
oz yes yes
no
lb:oz yes no
no
g yes yes
no
CONFG
SubMenu1 SubMenu2 Option Default Parameter Description Comment