Installation 8200 Compressor
Compressor Installation Installation, Operation, and Service Instructions
8040353 Brooks Automation
4-2 Revision AA
Compressor Installation
Installation of your compressor requires no special tools other than those supplied in
the Installation and Scheduled Maintenance Tool Kit.
Preparing the Compressor Input-Power Cable
To supply input power to the 8200 compressor requires the fabrication of a 600-volt
power cable that has an SO-4 conductor, 600-volt rating neoprene jacket and 14-gauge
or 2.3 mm
2
wire.
Unit must be wired by an authorized electrician in accordance with the national Elec-
trical Code, ANSI/NFPA 70-1987, as well as the local codes. This shall include instal-
lation of a readily accessible disconnect device into the fixed wiring supplying power.
An insulated earthing conductor that is identical in size, insulation material and thick-
ness to the earth and unearth branch circuit supply conductors, except that it is green
with or without one or more yellow stripes is to be installed as part of the branch cir-
cuit which supplies the unit or system. The earthing conductor described is to be con-
nected to the earth at the service equipment, or supplied by a separately derived
system at the supply transformer or generator.
Proceed as follows:
1. Prepare the input power cable by terminating each of the four conductors with
a #10 ring terminal. Follow the terminal manufacturer’s instructions to insure
proper crimping.
2. Disassemble the electrical terminal enclosure cover, mounted on the compres-
sor rear panel, as shown in Figure 4-1 on page 4-4. Remove the two screws
securing the cover and lift it off.
3. If necessary, back off strain relief screws.
High Voltage
High voltage electric shock could cause severe injury or loss of life.
Do not connect the compressor to the power source at this time.
Complete the preparation and panel reinstallation before electrically
connecting the compressor.