6. Replacing Parts
14.
Con
nect the Pump Tube (3) to the Drain Joint (2).
(3)
(2)
15.
Pass th
rough the Pump Tube at the side of the Frame. Pay attention that the Pump Tube should not
bend around the outlet.
16. Ins
ert the Pump Holder to the Frame and fix it with the left/right Screws (1) with tightening torque 1.5 N·m.
(1)
(1)
17. Attac
h the Covers. (Refer to “6-1-2. Assembling/Disassembling of the Covers”.)
18. Adjust the firmware (Tube pump) with GT-3 Service Tool. Refer to the end of “6-1-20.Suction Pump
Assy”.