3.4.1. Storage and Recall
of
MEASUREMENT SETUPS
The
2032 stores
23
MEASUREMENT SETUPS named
Dn,
Sn,
Wn,
1,
2,
3,
...... , 19, 20,
(n
=
1,
2,
3,
.... ,
19,
20). The setup in use is identified by the MEASUREMENT SETUP label
field,
at
the head
of
the MEASUREMENT SETUP. All
23
setups are
stored
when
electri-
cal
power
to
the 2032 is switched off. Setups 1
to
10 are user-defined, and are
stored
using the SAVE SETUP pushkeys, see Section,4.2.3. Setups
11
to
20 are
factory
de-
fined and held in read-only memories, see
Chapter
10. Setups 1
to
20
can be recalled
by pressing SETUP LABEL "Measurement", entering the number
of
the required setup
via
the FIELD ENTRY numeric keyboard, and pressing "ENT",
or
by pressing SETUP
LABEL
"Measurement" and using the FIELD ENTRY knob
or
increment/decrement
pushkeys. As
an
aid
to
selection, the setups can be listed (Fig.3.4)
by
pressing SETUP
LABEL
"Measurement" and then pressing the
upper
right
hand (blank) key
of
the FIELD
ENTRY numeric keyboard. This key can then be used
to
toggle
the Display between a
listing
of
the MEASUREMENT SETUPs and the selected MEASUREMENT SETUP.
Fig.3.4. A
listing
of
the
available
MEASUREMENT SETUPS
on
the 2032
Display
3.4.2.
Definition
of
the
MEASUREMENT SETUP
in
use
The
2032 always displays the MEASUREMENT SETUP being used
for
an ongoing mea-
surement, and when a measurement is started,
it
will always be with the displayed
MEASUREMENT SETUP. Should a display
format
be used where the MEASUREMENT
SETUP is absent, then an ongoing
or
just
started measurement will be defined by the
MEASUREMENT SETUP
last displayed. This setup will be returned
to
the 2032 Display
the next
time
a display
format
with the MEASUREMENT SETUP is selected.
3.4.3. Documentation, Stored, and
Working
Setups
Dn,
Sn,
and
Wn
denote Documentation Setup, Stored Setup, and
Working
Setup, n
being the MEASUREMENT SETUP
from
which they were derived. When a MEASURE-
MENT SETUP is
recalled,
it
is identified by the label "Setup n" on the 2032 Display.
Should
any parameter in the setup be changed either
before
or
during a measurement
it
becomes a
Working
Setup, identified as "Setup Wn". Should any
parameter
in the
Measurement Setup be changed
after
the measurement has been completed, the setup
used
to
obtain the displayed results becomes a Documentation Setup, labelled "Setup
Dn".
Should a measurement be
stored
in the 2032 memory, then the accompanying
setup becomes a Stored Setup,
labelled "Setup
Sn"
when
it
is recalled
to
the Display.
The Documentation, Stored, and
Working
Setups may be accessed using the FIELD
ENTRY knob
or
increment I decrement push keys,
or
the numeric keyboard
entry
codes
-2, -1,
or
0,
respectively.