DANGER
Strong magnetic field (non-ionizing radiation)!
Effect on living beings!
During
the charging process there is a strong magnetic field between CPM and GPM, which exceeds
the limits for long
-term exposure of living beings.
In order to exclude acute effects, such as muscle
- and nerve stimulation, as well as consequential
damage, no
body parts may get into and around the space between the GPM and CPM during the
charging
process.
In addition, jewelry (rings, wristwatches, etc.) can heat up considerably and become damaged or lead
to burns.
People with a cardiac pacemaker, implanted defibrillator or other implants should keep away from the
vicinity of the system during the charging
process.
Keep animals away from the system during operation.
NOTICE
Damage to the HV-Battery:
Make sure, that the voltage ranges of the device and the HV-battery are identical!
Use only technically suitable and high-quality cabling! In case of uncertainties, please contact
BRUSA Elektronik AG beforehand at the manufacturer address specified in chapter 3.3.
NOTICE
Damage to the devices:
Regularly check the GPM for defects and report defects or damage to your customer service.
A visibly damaged GPM must be replaced, in order to exclude the risk of injury. Do not touch
an obviously damaged GPM under any circumstances
Check generally when connecting the GPM, that the mains voltage is in the permissible range
(see chapter 4.2.1)!
Do not establish a low-resistance connection between the HV contacts, the housing- as well
as the LV-contacts under any circumstances! This leads to malfunctions and ultimately to the
destruction of the device!
The components of the ICS must not be opened under any circumstances!
Do not install and operate the GPM in the immediate vicinity of heat sources!
A high ambient temperature reduces the service life! Therefore continuously ensure for
sufficient cooling of the device!
Prevent any penetration of liquids in the device (e.g. during installation work)! The penetration
of liquids leads to a short circuit and subsequently to damage of the device!
If any liquid has entered, do not start the device again under any circumstances and contact
your customer service!