12.2.3 Mechanical Data of the CPM
PART OF THE SYSTEM
PHYSICAL SIZE [UNIT] CHARACTERISTIC VALUE/(-RANGE)
12.2.4 Mechanical Data of the GPM
PART OF THE SYSTEM
PHYSICAL SIZE [UNIT] CHARACTERISTIC VALUE/(-RANGE)
Weight [kg] approx. 49
12.3 Requirements on Specialist Personnel
12.3.1 Specialist Requirements
The work steps described in this manual for assembly, installation, disassembly and disposal may only be
performed by qualified specialist personnel (mechanical installation) or by a qualified electrician (electrical
installation), who, based on their professional education, knowledge and experience as well as knowledge of the
relevant standards, can assess and perform the work steps described in the installation instructions and recognize
any dangers.
12.3.2 Health-related Requirements
WARNING
Risk of injury due to electromagnetic field!
During inductive charging an electromagnetic field is
generated under the vehicle.
Cardiac pacemakers and medical implants can be impaired
.
Do not reach under the vehicle or perform maintenance work on the vehicle during the charging
process
.
The warning of dangers due to electromagnetic radiation also applies for specialists. Electromagnetic radiation can
be particularly dangerous for people with medical implants, especially people with cardiac pacemakers.
12.4 Information about Protective Equipment
12.4.1 Protective Equipment during Transport and Storage
For the installation the following protective equipment must be worn, to prevent possible injuries in the respective
work steps:
Transport / Removal / Storage: Protective gloves against mechanical risks and safety shoes
45
Operation Manual
Inductive Charging System
ICS115