SITUATION TROUBLESHOOTING
The vehicle (the drive battery) is
not completely charged.
Check, whether the charging time for the
complete charge of the battery was
sufficient. (Is the charging process resumed when you resume the charging
function?)
Check, whether the GPM and its immediate environment is free of foreign
objects. If necessary clear it, taking into consideration the
information specified in
chapter
8.1.2
. Perhaps the charging operation could not be completed in the
charging time provided due to the presence of
foreign objects.
Check, whether the charging function has been and can be interrupted by
people or animals. If necessary, prevent the access to the charging station.
Perhaps the charging process was stopped by a person or animal and therefore
could not
be completed in the charging time provided.
If the error still occurs, contact customer service.
The vehicle (the drive battery) is
not completely charged,
although the charging operation
was indicated as completed.
Check, whether consumers in the
vehicle (e.g. radio, light, navigation?) were
switched on, so that after charging up, the drive battery was discharged again.
If the error still occurs, contact customer service.
The ICS System can no longer
be used / it is switched off.
Check, whet
her the GPM can be supplied with power. For this, establish
whether the power supply for the GPM has been interrupted by electrical safety
devices. If so, re
-
establish the power supply for the GPM, by switching on the
electrical safety device.
Contact customer service
8 Maintenance
DANGER
Never perform maintenance measures during operation of the ICS!
Strong magnetic field (non-ionizing radiation)!
Influence on electrically conductive objects!
the charging process there is a strong magnetic field between CPM and GPM, which exceeds
-term exposure of living beings.
In order to exclude acute effects, such as muscle
- and nerve stimulation, as well as consequential
body parts may get into and around the space between the GPM and CPM during the
process.
In addition, jewelry (rings, wristwatches, etc.) can heat up considerably and become damaged or lead
to burns.
People with a cardiac pacemaker
or implanted defibrillator should keep away from the vicinity of the
system during the charging
process.
Keep animals away from the system during operation.
Operation Manual