6.3.4.8. Brownout Disable
This option turns off the high voltage brownout detection function in the
outdoor unit control. After the selection is made, touch SAVE.
Brownout Disable: On or Off. Default = Off
6.3.4.9. Low Air Multiplier
Adjusts the airflow speed on non-communicating two-stage units.
Choose 0.65 for units with a Bristol compressor, choose 0.80 (default) for
units with a Copeland scroll compressor.
6.3.4.10. Energy Efficiency
This option is used to input the published ratings of the installed air
conditioner or heat pump as part of the energy tracking calculation. After
the ratings are entered, touch SAVE.
6.3.5. Heat Source Lockout
First touch SETUP, then touch HEAT SOURCE LOCKOUTS to set up
the parameters for the AC/Heat Pump unit.
For hydronic heat applications, this option allows the installer to set the
lockout temperatures below which only the hydronic coil will operate,
and the lockout temperature above which the hydronic coil will not
operate. After the selections are made, touch SAVE.
A12149

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant Evolution Connex Control SYSTXBBECC01-C and is the answer not in the manual?

Bryant Evolution Connex Control SYSTXBBECC01-C Specifications

General IconGeneral
BrandBryant
ModelEvolution Connex Control SYSTXBBECC01-C
CategoryThermostat
LanguageEnglish

Related product manuals