2. Introduction
The Evolution System consists of several intelligent communicating
components which include the Evolution™ Connex™ Control (or User
Interface), variable speed furnace or FE fan coil, 2-stage AC and HP,
(including Geothermal units), multi-stage AC and HP, variable capacity
HP and AC units, and Evolution Connex System Package units which
continually communicate with each other via a four-wire connection
called the ABCD bus. Commands, operating conditions, and other data
are passed continually between components over the ABCD bus. The
result is a new level of comfort, versatility, and simplicity.
All Evolution System furnaces or fan coils are variable-speed and multi
stage for maximum flexibility, efficiency, and comfort. They support
controlled ventilation, humidification, dehumidification, and air quality
control. Either an Evolution System (communicating), or a standard
single-stage 24VAC controlled outdoor unit may be used.
When using conventional single-stage outdoor units, the Evolution
System furnace or fan coil provides the 24 volt signals needed to control
them. When using multi-stage conventional outdoor units or heat pumps,
an Evolution System Network Interface Module or “NIM” (P/N
SYSTXBBNIM01 may be required to provide additional control outputs.
Also, the NIM with a translator board (SYSTXXXTRB01) allows
connection of a Bryant HRV or ERV without the need for separate wall
control.
When using a Bryant HRV or ERV with a zoned system, the Evolution
System Zone board with a translator board (SYSTXXXTRB01) allows
connection of a Bryant HRV or ERV without the need for separate wall
control or NIM.
All system components are controlled through the wall mounted
Evolution Connex Control, which replaces the conventional thermostat