Using the controls safely
4
Logamatic 2107 controls - We reserve the right to make any changes due to technical modifications. 13
4 Using the controls safely
4.1 Correct use
The Logamatic 2107 controls is designed to control and
monitor heating systems in single family homes and
small office buildings. It controls the room temperature
following a heating program, and sets DHW
temperature.
4.2 For your safety
The Logamatic 2107 controls has been designed and
built in accordance with current standards and safety
requirements.
However, accidents resulting from inappropriate
handling of this device cannot be completely excluded.
Only operate the Logamatic 2107 controls as
intended and when it is in perfect working order.
Let your local heating contractor instruct you in the
proper operation of your system.
Please read these operating instructions carefully.
4.3 Cleaning the control panel
The Logamatic 2107 control panel is housed in a
resilient plastic housing.
z Only clean the controls with a damp cloth and a mild
cleaning agent.
4.4 Disposal
z Dispose of the Logamatic 2107 controls packaging in
an environmentally responsible manner.
z Dispose of defunct controls in an environmentally
acceptable form, through an approved organization.
WARNING!
RISK OF LIFE
z In an emergency, switch off at the
emergency shutoff switch outside the
boiler room. Let your local heating
contractor immediately remedy all
heating system faults.
WARNING!
RISK OF LIFE
from electric shock.
z All tasks listed in these service
instructions, which require the opening
of the control panel, must only be
carried out by trained personnel.
WARNING!
RISK OF SCALDING
The DHW tank temperature is preset to
140°F (60°C). There is a serious risk of
scalding from hot water above 122°F
(50°C). Verify that your heating contractor
has installed a thermostatically controlled
mixing valve. Please note that pipes and
fixtures can get very hot.
z In such cases, only ever draw-off
mixed water (hot and cold).
CAUTION!
SYSTEM DAMAGE
from frost.
The heating system can freeze up if the
control panel has been switched off.
z Protect your heating system against
frost when freezing temperatures are
expected.
z With the controls switched OFF, drain
the water from the boiler, the DHW
tank and the pipes of the heating
system.

Other manuals for Buderus Logamatic 2107

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buderus Logamatic 2107 and is the answer not in the manual?

Buderus Logamatic 2107 Specifications

General IconGeneral
CategoryControl Systems
TypeHeating Control Unit
Voltage230 V
Frequency50 Hz
Protection classIP20
Ambient temperature0°C
ApplicationHeating systems

Related product manuals