7 | In Operation
30 / 56 0870215096_RA0760A_PLUS_-0001_IM_en
Enable or disable the external dry contact.
Once the external dry contact enabled, its state is visible:
External dry contact state
Contact open Contact closed
Below the chronogram of the external dry contact:
Pump
started
Pump
stopped
Pressure
(ex: >50 mbar)
Pressure
(ex: ≤50 mbar)
Pump
stopped
Pump
started
Time delay
(ex: 10 s)
Vacuum
pump
Relay
KA1 NC
Relay
KA1 NO
Pin 9
24V