0870215096_RA0760A_PLUS_-0001_IM_en 49 / 56
The machine does not reach
the usual pressure on the
suction connection.
Oil level too low. Top up oil,
see Filling Oil [16].
The inlet filter cartridge (IF)
is partially clogged.
Replace the inlet filter
cartridge (IF).
Internal parts are worn or
damaged.
Repair the machine (con-
tact Busch).
The machine runs very nois-
ily.
Worn coupling (CPL). Replace the coupling
(CPL).
Stuck vanes. Repair the machine (con-
tact Busch).
Defective bearings. Repair the machine (con-
tact Busch).
The machine runs too hot. Insufficient cooling. Remove dust and dirt
from the machine.
Check the heat exchanger
(AHE).
Ambient temperature too
high.
Observe the permitted
ambient temperature.
Oil level too low. Top up oil,
see Filling Oil [16].
The exhaust filters (EF) are
partially clogged.
Replace the exhaust filters
(EF), see Exhaust Filter
Change [45].
The machine fumes or ex-
pels oil droplets through the
gas discharge.
The exhaust filters (EF) are
partially clogged.
Replace the exhaust filters
(EF).
An exhaust filter (EF) with o-
ring is not fitted properly.
Ensure the correct posi-
tion of the exhaust filters
(EF) and the o-rings.
The float valve (FV) does
not work properly.
Check float valve and the
oil return line, repair it if
necessary (contact Busch).
Abnormal oil consumption. Oil leaks. Replace seals (contact
Busch).
The float valve (FV) does
not work properly.
Check float valve and the
oil return line, repair it if
necessary (contact Busch).
The machine runs at atmo-
spheric pressure for a long
period.
Make sure that the ma-
chine operates under va-
cuum.
The oil is black. Oil change intervals are too
long.
Drain the oil and fill in
new oil, see Oil Change.
The machine runs too hot. See problem "The ma-
chine runs too hot".
The oil is emulsified. The machine sucked in li-
quids or significant amounts
of vapour.
Flush the machine (con-
tact Busch).
Clean the filter of the gas
ballast valve (GB).
Modify the operational
mode (see Conveying
Condensable Vapours
[29]).

Other manuals for BUSCH R 5 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BUSCH R 5 series and is the answer not in the manual?

BUSCH R 5 series Specifications

General IconGeneral
BrandBUSCH
ModelR 5 series
CategoryWater Pump
LanguageEnglish

Related product manuals