Troubleshooting | 12
0870215096_RA0760A_PLUS_-0001_IM_en 51 / 56
Table 2
Message Possible Cause Remedy
Fan breaker
(alarm)
The circuit breaker of the
cooling fan has tripped.
Refer to schematic and
reset the breaker.
VFD breaker
(alarm)
The circuit breaker of the
variable frequency drive has
tripped.
Refer to schematic and
reset the breaker.
Analog input module dis-
connected
The analog input module is
not connected or has been
disconnected.
Refer to schematic and
reconnect the analog in-
put module.