Appendix A
Direct Import to Compatible Programs
I
D1430/2 English
In this example:
Line 1 shows the alarm 1 setpoints (code ‘1’) for all 4
sensors.
Line 2 shows the alarm 2 setpoints (code ‘2’) for all 4
sensors. Alarm points are only recorded when the unit is
turned on, indicating the unit has just been activated.
Lines 3 and 4 show normal operation – no gas readings or
alarms.
Line 5 shows an H
2
S low alarm. CO and LEL gases are
present below alarm levels. The unit is in low alarm.
Line 6 shows the H
2
S sensor in high alarm. The unit is
sounding high alarm.
Line 7 shows the H
2
S in high alarm, and CO and LEL in low
alarm. The unit is sounding multi-alarm.
Line 8 shows the unit in pump alarm. The sampling pump
has been blocked, and gas readings are not available. The
unit is sounding pump alarm.
Line 9 shows the unit emitting a low-battery alarm. There are
no gas alarms.
Line 10 shows the unit automatically shutting down because
of a low battery. The battery is low, and the unit is sounding
an automatic shutdown alarm.