- Correct the horizontal (closing) position, in the same way.
N.B.: procedure to carry out after making electrical connections to the control panel.
Close the inspection hatch and power up the system. Activate the arm to check whether it is parallel to the road surface when close and
at about 89° when open.
Warning!The inspection hatch must be closed for opening and closing of the barrier arm to be safe and functional.
- To adjust the vertical (opening) position of the barrier arm, close it, open the inspection hatch and turn the screw clockwise (to
increase the the barrier-arm travel, or, counterclockwise to decrease it. n.
Note: before stopping completely the barrier-arm goes through a
slowing down phase thanks to a cam that triggers the slow-down
microswich. the microswitch is set at maximum advance. If you
wish to delay the slowing-down pahse, loosen the screws of the
o micro-switch ledge screws p, and position them outwards, see
drawing.
Adjusting the limit switches

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 4 SERIES and is the answer not in the manual?

CAME GARD 4 SERIES Specifications

General IconGeneral
Power Supply230V AC
Motor Power300W
Operating Temperature-20°C to +55°C
Protection RatingIP54
ModelGARD 4
TypeBarrier Gate
Boom Length4 meters

Related product manuals