p. 16 - Manual FA01332-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Signalling devices
1 Additional light
Increases illumination in the maneuvering area.
Maximum contact capacity 10 - E1
26 V AC/DC - 20 W
2 Additional flashing light
It flashes during the operator opening and closing
phases.
Maximum contact capacity 10 - E1
26 V AC/DC - 20 W
3 Operator status warning light
It warns of the operator status.
Maximum contact capacity 10 - 5
24 V AC/DC - 3 W
4 RGB LED strip and/or RGB corona
Maximum capacity 13.5 W
3fee4254-1c6e-4b0e-87ec-ba01e7f8aeb5Flashing red LEDs: cdeb843f-a1d9-491d-b501-6864acfa4fafOperator in movement.
495af760-e871-45b5-bdbc-056ee72fc680Green LEDs on: be000f05-c867-4a2c-a412-3069b82f5317Operator open.
2176482b-d2f0-4a24-a8d1-724f792477d8Red LEDs on: 616a9b31-61f9-4b20-974e-a4ea66eb5df9Operator closed.
830965ef-bfb1-4880-9a6e-156194978f48Red LED flashing fast: 9afb7ded-a281-4ef9-9a23-2f053e3aedb2Inspection hatch open,
gearmotor unlocked or boom drop-away.
A B GND A B GND RGB
2
10
S1
GND
AB
11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
FA
FC
FCA CM1 FCC CM2
MOTOR
BLOCK
+
-
1
2
3
4
Command and control devices
2
24
10
S1
GND
AB
11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ
FA
FC STB
TAMPER
+
-
32
1
4 6 7 8 9
5
1 Antenna with RG58 cable
2 Card reader
3 Transponder selector switch
4 Keypad selector
5 TEMPORARY STOP button (NC contact)
It stops the boom and excludes the automatic closing; after 15 seconds the
boom opens slowly.
If the contact is not used, it must be deactivated during the
programming.
c2ad2b4c-af33-4cf0-8187-a13e897192c86 Control device - f178a547-53f4-4963-8eee-c27de5cc1ec7OPEN ONLY function - 84213bc6-490c-4d9a-b4c5-ee2c5de78b75NO contact
For opening only.
The contact can be programmed for the hold-to-run function.
c2ad2b4c-af33-4cf0-8187-a13e897192c87 Control device - f178a547-53f4-4963-8eee-c27de5cc1ec7OPEN ONLY function - 84213bc6-490c-4d9a-b4c5-ee2c5de78b75NO contact
For opening only.
The contact must be used only for operators working in paired mode.
c2ad2b4c-af33-4cf0-8187-a13e897192c88 Control device - 770f0cc2-275f-4430-9aa5-de697d3e06daCLOSE ONLY function - 84213bc6-490c-4d9a-b4c5-ee2c5de78b75NO contact
For closing only.
The contact can be programmed for the hold-to-run function.
c2ad2b4c-af33-4cf0-8187-a13e897192c89 Control device - bda334dd-4b0e-4b2e-9f5b-ef3bf25ddfceOPEN-CLOSE function - 84213bc6-490c-4d9a-b4c5-ee2c5de78b75NO contact
For opening and closing.