Campbell CR1000X - Device Configuration Utility Settings (Continued)

Campbell CR1000X
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keyword Information and Location
IncludeFile
This setting specifies the name of a file to be implicitly included at the
end of the current CRBasic program or can be run as the default
program. In order to work as an include file, the file referenced by this
setting cannot contain a BeginProg() statement or define any
variable names or tables that are defined in the main program file.
This setting must specify both the name of the file to run as well as on
the device (CPU:, USR:, or CRD:) on which the file is located. The
extension of the file must also be valid for a datalogger program (.dld,
.cr1x).
See also File management via powerup.ini (p. 43).
l String data type
Where to find:
l Settings Editor tab in Device Configuration Utility: Advanced
|Include File Name
IPAddressCSIO
Arrays that specify the IP addresses of the internet interfaces that use the
CS I/O bridge protocol. If a value is specified as zero (the default), the
datalogger will use DHCP to configure the IP address, network mask,
and default gateway for that interface.
l String data type
Where to find:
l Settings Editor tab in Device Configuration Utility: CS I/O IP | IP
Address
9. Tips and troubleshooting 146

Table of Contents