LASER CLASS 730i/720i/710 Chapter 4: Maintenance and Service
4-23
No. Tx or Rx Definition
##0759 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-MPS
##0760 [TX ] In ECM transmission, no significant signal can be received after
transmission of PPS-EOM, and the allowed number of
procedure signal re-transmissions was exceeded
##0762 [TX ] In ECM transmission, DCN was received after transmission of
PPS-EOM
##0763 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-EOM
##0764 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-EOM
##0765 [TX ] In ECM transmission, no significant signal can be received after
transmission of PPS-EOP, and the allowed number of procedure
signal re-transmissions was exceeded
##0767 [TX ] In ECM transmission, DCN was received after transmission of
PPS-EOP
##0768 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-EOP
##0769 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-EOP
##0770 [TX ] In ECM transmission, no significant signal can be received after
transmission of EOR-NULL, and the allowed number of
procedure signal re-transmissions was exceeded
##0772 [TX ] In ECM transmission, DCN was received after transmission of
EOR-NULL
##0773 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-NULL
##0774 [TX ] In ECM transmission, ERR was received after transmission of
EOR-NULL
##0775 [TX ] In ECM transmission, no significant signal can be received after
transmission of EOR-MPS, and the allowed number of
procedure signal re-transmissions was exceeded
##0777 [TX ] In ECM transmission, DCN was received after transmission of
EOR-MPS
##0778 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-MPS
##0779 [TX ] In ECM transmission, ERR was received after transmission of
EOR-MPS