EasyManua.ls Logo

Canon LASER CLASS 710 - Page 105

Canon LASER CLASS 710
436 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LASER CLASS 730i/720i/710 Chapter 4: Maintenance and Service
4-22
No. Tx or Rx Definition
##0290 [TX ] After transmitting MPS, a signal other than PIN, PIP,MCF,
RTP, or RTN was received
##0295 [TX ] For the auto alarm notification function, the other party does not
have an NTT remote maintenance function
##0670 [TX ] In V.8 late start, the V.8 ability was detected in DIS from the
other party and, in response, CI was transmitted; however, the
procedure failed to advance, causing a T1 time-over condition
##0671 [RX ] In V.8 call arrives, the procedure fails to advance to phase 2 after
CM detection, causing a T1 time-over condition
##0672 [TX ] In V.34 transmission, the procedure fails to move from phase 2
to phase 3 and later, causing a T1 time-over condition
##0673 [RX ] In V.34 reception, the procedure fails to move from phase 2 to
phase 3 and later, causing a T1 time-over condition
##0674 [TX ] In V.34 transmission, the procedure fails to move from phase 3
or phase 4 to a control channel or later, causing a T1 time-over
condition
##0675 [RX ] In V.34 reception, the procedure fails to move from phase 3 or
phase 4 to a control channel or later, causing a T1 time-over
condition
##0705 [TX ] In CHT transmission, DCN was received after detecting NACK
##0711 [TX ] In CHT transmission, REJ was received after transmission of an
image signal
##0750 [TX ] In ECM transmission, no significant signal can be received after
transmission of PPS-NULL, and the allowed number of
procedure signal re-transmissions was exceeded
##0751 [TX ] In ECM transmission, a signal other than MCF, PPR, or RNR
was received after transmission of PPS-NULL
##0752 [TX ] In ECM transmission, DCN was received after transmission of
PPS-NULL
##0753 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-NULL
##0754 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-NULL
##0755 [TX ] In ECM transmission, no significant signal can be received after
transmission of PPS-MPS, and the allowed number of procedure
signal re-transmissions was exceeded
##0757 [TX ] In ECM transmission, DCN was received after transmission of
PPS-MPS
##0758 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-MPS

Table of Contents

Related product manuals