LASER CLASS 730i/720i/710 Chapter 4: Maintenance and Service
4-59
5.6 New SSSWs/Parameters Added to this Model
#1 SSSW
SW01 (service soft switch 01: error management )
Bit Function 1 0
0 Service error code Output Not output
1 Error dump list Output Not output
2 Enter password at confidential No Ye s
Rx image data transfer
3 Copy function No Ye s
4 (New) ##300 series service error code Output Not output
5 Not used
6 Date & Time setting restriction
Setting restricted Setting possible
7 User setting restriction
Setting possible Setting restricted
[Bit 4]
When “Output” is selected, ##300 series Service error codes are displayed and in reports.
When “Not output” is selected, no Service error codes are displayed.
SW06 (service soft switch 06: scan condition settings)
Bit Function 1 0
0 Document feed after DES on No feed Feed
1 Prescan for document scanning No prescan Prescan
2 Not used
3 (New) Stamp option Yes No
4 Document scan width LETTER A4
5 Recording paper output for long First page Divided onto
image copy only multiple pages
6 Copy function resolution Variable
Always fine mode
7 Superfine mode setting when Set Not set
AUTO key selected
[Bit 3]
If a stamp unit option is installed, set this switch to 1. If it is set to 1, the Stamp button on
the operational panel and the “STAMP ACTION” menu in Users Data becomes effective.
manuals4you.commanuals4you.com