13
rel. 2.7 - 16.11.2018
ENG
"Passive probes" +030220658 -
NTC*LT sensor assembly instructions using the cable tie tension tool
1) Place the sensor on the pipe, wrap and secure
the cable ties around the two ends;
2) On the cable tie tension tool (P/N CM00000006)
set the tension to 250N (position 6 on the index);
3) Use the tool to tighten and then cut the cable
tie 1209874AXX;
4) Wrap the electrical cable twice around the pipe
at the base of the sensor;
5) Cover the sensor with thermal insulation for at
least 10 cm around the end of the cap and the
wound cable;
2.10 Models NTC*PS*
Storage conditions -50T105 °C
Operating range -50T105 °C
Connections Stripped and soldered ends, dimensions: 4±1 mm
Sensors NTC 10 kΩ ±1% a 25 °C Beta 3435
Dissipation factor (in air) 2 mW/°C
Thermal constant over time (in air) ca. / approx. 50 min (V=1 m/s)
Cable Two-wire with double sheath, AWG22, tinned copper with electrical resistance ≤73.9 Ω/km - Insulation: TPE speci-
fic for immersion in water on outer sheath, PP/Co inside on wires, OD 3.30+/-0.10 mm
Sensitive element index of protection IP67
Case Santoprene grey RAL7032
Compatible for food contact
Classification according to protection against
electric shock (sensitive element and cable)
Basic insulation for 250 Vac
Category of resistance to heat and fire Flame retardant
Tab. 2.i
98
20
105 L =*
CAREL code
Magnetic base
Make a hole for fastening by screw
Fig. 2.t
* = see table of product codes in price list