22
rel. 2.7 - 16.11.2018
ENG
"Passive probes" +030220658 -
6. PT100 PROBE TECHNICAL SPECIFICATIONS
6.1 Models PT100
Storage conditions -50T250 °C
Operating range elemento sensibile PT100000A1: -50 °C…+250 °C
PT100000A2 : 0 °C…+400 °C
Sensor Pt100 Class B in accordance with DIN IEC751, 3 wire
Precision +/- class B=(0,005xt)+0,3, a 100°C = ±0,8°C
Connections aliment. e uscita Stripped ends, dimensions 6±1mm
Cable PT100000A1: silicone rubber HALOGEN COMPOUNDS ≤ 1.1 x 10-3 mg/g
PT100000A2: 3x0.5 mm2 fibreglass wire and secondary insulation
Dissipation factor (in air) 0,3 K/mW at 0 °C
Thermal constant over time (in air) ca./approx 20 s
Category of resistance to heat and fire Range -20 °C +200°C for PT100000A1, +500 °C for PT100000A2
Insulation resistance >500 Mohm / 250 V
Dielectric strength 250 Vac (code PT100000A1 only) not applicabie for PT100000A2
Primary insulation (porbe and cable) 250 Vac
Sensitive element index of protection IP65
Sensitive element housing AISI 316 stainless steel
Tab. 6.a
100
L =*
**
Ø 6
Fig. 6.a
* = see table of product codes in price list
** = 3-wires cable compensates for the resistance introduced by the cable
rosso
rosso
bianco