Foot Switch Assembly Operation
PN 9585 Foot Switch Assembly (Model 36A/36B, Model 93, or Model 97A)
For Model 36A/36B: The interface between the Model 36A/36B and the Model 860 may be
controlled by a PN 9585 foot switch assembly. To install the foot switch assembly, insert the
foot switch assembly connector at the end of the foot switch cable into the PN 9583 accessory
board kit previously installed on the back of the Model 36A/36B.
After installing the foot switch assembly, press the MENU button to toggle through the
processor options and press ENTER when “WIRE COILER” is shown. Confirm “WIRE
COILER ON” and press ENTER. Then press CLEAR to toggle between “FOOT SWITCH
ON” and “FOOT SWITCH OFF” and press ENTER.
1. When processing material with a foot switch assembly, the Model 860 “RESTART
DWELL” should be set to 0.
2. Press the RUN button on the Model 36A/36B to begin processing.
3. After completion of the first piece of material, the display will read the following: “Press
foot switch or press STOP.” Press and release the foot switch assembly to continue
processing material, or press the STOP button to quit.
a. If the STOP button is pressed, the display will read the following: “STOP
activated, press ENTER to reset.”
4. When the programmed number of pieces is complete, the display will read the following:
“Processing complete, please press ENTER.”
For Model 93 or Model 97A: The interface between the Model 93 or Model 97A and the Model
860 may be controlled by a PN 9585 foot switch assembly. To install the foot switch assembly,
insert the foot switch assembly connector at the end of the foot switch cable into the PN 9583
accessory board kit previously installed on the back of the Model 93 or Model 97A.
After installing the foot switch assembly, press the MENU button to toggle through the
processor options and press ENTER when “WIRE COILER ON/OFF” is shown. Confirm
“WIRE COILER IS ON” and press ENTER. Then press the corresponding “ON” or “OFF”
arrow to toggle between “FOOT SWITCH IS ON” and “FOOT SWITCH IS OFF” and press
ENTER.
1. When processing material with a foot switch assembly, the Model 860 “RESTART
DWELL” should be set to 0.
2. Press the RUN button on the Model 93 or Model 97A to begin processing.