www.cas-usa.com 19
4.5 MISC Submenu:
MISC
SUBMENU1 REMARK
CODE
display ADC's code, this code can be after no-filter, filter1 or filter2; details refer to
section14
VOL
display voltage; calibrate voltage; details refer to section15
DATE
display date and set date; details refer to section17
TIME
display time and set time; details refer to section16
VER
display firmware version; details refer to section18
4.6 TEST Submenu:
TEST
SUBMENU1 REMARK
DISP.TST
test LCD or LED; details refer to section19
COM1.RD
test COM1 receiving; details refer to section21
COM1.TD
test COM1 transmitting; details refer to section22
COM2.RD
test COM2 receiving; details refer to section21
COM2.TD
test COM2 transmitting; details refer to section22
KEY.TST
test keys and buzzer; details refer to section20

Related product manuals