25. Meaning of Some Symbols and Troubleshooting
25.1 Meaning of Symbols:
25.1.1 0﹉﹉﹉﹉ ------ Zero is over the setting range
25.1.2 0﹍﹍﹍﹍ ------ Zero point is below the setting range
25.1.3 Ad﹉﹉﹉ ------ Signal to ADC is over max. range)
25.1.4 Ad﹍﹍﹍ ------ Signal to ADC is below min. range
25.1.5 ﹉﹉﹉﹉ ------ Weight is over upper limitation, or display data is over limitation
25.1.6 ﹍﹍﹍﹍ ------ Weight is below lower limitation
25.1.7 EEP.E1 ------ CONFIG or CAL parameters are not correctly set
25.1.8 EEP.E2 ------ USER parameter is not correctly set
25.1.9 Lo.bAt ------ Battery voltage is lower than setting.
25.1.10 CAP.- - - ---- Next displaying content is Capacity
25.1.11 CAP.ER ----- Parameters about Capacity is not correct
25.1.12 CAL.Px ----- Calibration on point(x)
25.1.13 CAL.OFF ----- Calibration Seal Switch is on OFF position
25.1.14 CAL.ON ----- Calibration Seal Switch is on ON position
25.1.15 CAL.Er ----- Calibration error, maybe input data or loaded weight is incorrect, unstable, un-linear
25.1.16 CAL.End ----- Calibration is end
25.1.17 OFF ----- Power OFF the indicator
25.1.18 STB.ER ------ Unstable time is lager than setting of USER-HOLD-STB.TIM
25.1.19 AC.xxxx ----- Accumulation times is xxxx
25.1.20 PR.TARE ----- To Preset TARE weight
25.1.21 COMP ---- To go to input COMPARE data mode
25.1.22 HIGH ----- To input HIGH limitation data of Comparison
25.1.23 LOW ----- To input LOW limitation data of Comparison
25.1.24 SPL.Lo ---------- Sample load weight of low point.
25.1.25 SPL.HI ----------- Sample load weight of high point.
25.1.26 SPL.PWT ------- Sample goods weight to calculate piece weight
25.1.27 INP.PCS --------- input pieces number of weighted goods
25.1.28 UNIT.KG --------- Unit kg is selected
25.1.29 UNIT.LB --------- Unit lb is selected
25.1.30 PWT.ER --------- Piece weight is error, it’s too small (<0.5d).
25.1.31 SPL.PCT -------- Sample goods weight to calculate
25.1.32 INP.PCT --------- input percentage of weighted goods
25.1.33 PCT.ER ---------- Unit-Percentage -Weight
is too small (<0.5d).
25.1.34 CACU.ER---------Internal calculation overflows