CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 27
percentage of samples and Press TARE key to confirm. If the calculated unit-percentage-weight is
less than 0.5d, the indicator will display Pct.Er and go back to percent weighing mode, otherwise,
after the reasonable unit-percentage-weight
being got, the scale will go back to percent weighing
mode. The got unit-percentage-weight
can be saved after the power off and can be used next time.
7.6 Check Percent (percentage compare) in Percent weighing mode:
7.6.1 To make percentage compare function available, CONFIG-FUNC-COMPAR menu item should set to
YES, and high and low limitation of percentage should be set correctly according to following steps:
7.6.2 In percent weighing mode, Press DATA key more than 3s to input compare data of high and low.
7.6.3 After HIGH being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input high
percentage number and press TARE key to confirm. Annunciator of Hi will be shown in this step.
Press ZERO key to exit and back to percent weighing mode.
7.6.4 After Low being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input low
percentage number and press TARE key to confirm. Annunciator of Lo will be shown in this step.
Press ZERO key to exit and back to counting mode.
NOTE: If High number is 0 or is equal or less than low number, the comparison will be disabled.
7.6.5 After a reasonable limitation is set and compare is be active, one of the annunciator, HI, OK, LO will
be lighted, and the beeper will sound according to its setting in USER-BEEP.
8. BMI Working Mode
8.1 To make BMI working Mode be available, CONFIG-FUNC-BMI menu item should be set to YES and
factory setting should be also enable this function
8.2 To enter BMI Working mode:
8.2.1 When CONFIG-FUNC-ACCUMU= Yes: If In normal weighing mode, percent weighing mode, or
counting mode, long press FUNC key, one of WEIGH/COUNT/PERCEN will be shown, use ACC or
PRINT key to select BMI, then press TARE to confirm go to BMI mode.
8.2.2 When CONFIG-FUNC-ACCUMU= NO: press BMI (ACC) key, go to BMI mode.
8.3 After scale go to this mode, “CM.xxx” (means: last input height is xxx cm) or “IN.xx.x” (means: last
input height is xx.x inch) will be displayed, and to wait for input height: (1)to change height unit to cm
or inch by pressing DATA key; (2) to change height number by using PRINT, ACC(BMI) keys
(3)Press and hold down PRINT or ACC(BMI) key will increase or decrease number fast, (4) Press
TARE key to confirm the input. Press ON/OFF key to exit input data mode and back to BMI working
mode. The range of height is 50-250cm(19.7-98.4inch) and default is 170cm(66.9inch)
8.4 In this mode, when BMI number is shown (BMI annunciator is on also), or weight number is shown
(BMI and kg or lb annunciator are on), Press ACC key to select weight or BMI number to be
displayed, when weight is displayed, the weight unit can be selected by pressing UNIT key, and BMI
and weight unit will be displayed at same time.
8.5 In this mode, when current net weight is less than NLD.RNG, the indicator will go to display weight
number if CONFIG-FUNC-ACCUMU= No; or the indicator will back to original working mode if
CONFIG-FUNC-ACCUMU= Yes.