CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 30
10.5 After Low being shown, last setting of low will be displayed, use PRINT, ACC, UNIT key to input new
number of low and press TARE key to confirm. Annunciator of Lo will be shown in this step. Press ZERO
key to exit and back to original working mode.
NOTE: If High number is 0 or is equal or less than low number, the comparison will be disabled.
10.6 After a reasonable limitation is set and compare function is be active, one of announciators HI, OK, LO
will be lighted, and the beeper will sound according to its setting in USER-BEEP.
10.7 For details, please refer to section of section5.13, 6.6 and 7.6
11. Accumulation
11.1 Accumulation function can be used in normal weighing mode, counting mode and percent weighing mode,
When this function is enabled, you can accumulate current net weight, piece, and percentage. Note, only
the load on scale is larger than USER-OTHER-NLD.RNG, the displayed positive number can be added
up. The accumulation times and total can be displayed or printed.
11.2 To make data accumulation function be available, CONFIG-FUNC-ACCUMU menu item should set to
MANUAL or AUTO, Following are details.
11.3 When CONFIG-FUNC-ACCUMU is set to MANUAL, the stable and positive displayed net weight (must
be larger than USER-OTHER-NLD.RNG), piece or percentage can be accumulated by long pressing
TOTAL key, and indicator will display accumulation times first, and then display total of number. To avoid
repeating accumulation for same load, one load only can be accumulated once. So, before a new load put
onto the scale, the original load should be removed and let load on scale be smaller than
USER-OTHER-NLD.RNG.
11.4 When CONFIG-FUNC-ACCUMU is set to AUTO, the stable and positive displayed net weight (must be
larger than USER-OTHER-NLD.RNG), piece or percentage can be accumulated automatically, and
indicator will display accumulation times first, and then display total of number. To avoid repeating
accumulation for same load, one load only can be accumulated once. So, before a new load put onto the
scale, the original load should be removed and let load on scale be smaller than
USER-OTHER-NLD.RNG.
11.5 To view total, when display number is zero, long pressing TOTAL key, and indicator will display
accumulation times first, and then display total of number. It will alternative display accumulation times
and weight (or quantity, or percentages) until the TOTAL key being pressed again.
NOTE:
When HOLD function is enable, and scale is working in PEAK HOLD mode ( CONFIG-HOLD=YES,
USER-HOLD-HLD.MOD=PS.PEAK/NG.PEAK), Accumulation function will be automatically
disabled!!!