EasyManua.ls Logo

CAS CI-100A - 6. Count Weighing Mode; Counting Mode Basics; Obtaining Piece Weight; 6.6 Check Counts (Compare)

CAS CI-100A
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 24
5.13 Check Weight in weighing mode:
5.13.1 To make weight compare function be available, CONFIG-FUNC-COMPAR item should set to YES,
and high and low limitation of weight should be set correctly according to following steps:
5.13.2 In weighing mode, Press down DATA key more than 3s to input compare data of high and low.
5.13.3 After HIGH being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input high weight
number and press TARE key to confirm. Annunciator of Hi will be shown in this step. Press ZERO
key to exit and back to weighing mode.
5.13.4 After Low being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input low weight
number and press TARE key to confirm. Annunciator of Lo will be shown in this step. Press ZERO
key to exit and back to weighing mode.
NOTE: If High number is 0 or is equal or less than low number, the comparison will be disabled, and the
input data has no limitation.
5.13.5 After a reasonable limitation is set and compare is be active, one of annunciator HI, OK, LO will be
lighted, and the beeper will sound according to its setting in USER-BEEP.
5.14 Enter Setup Mode:
5.14.1 If need to set configuration parameters, set user parameters, calibrate the scale, set current date or
time, test some hardware… It’s need to long press SETUP key to enter setup mode
5.14.2 After Entering Setup Mode, the main menu item CONFIG will be shown first.
5.14.3 In Setup mode, use to select wanted submenu and
wanted menu item, select wanted choice, set wanted number, confirm and save data, or exit this
mode. Please refer the “4.Operation Menu Structure”.
6. Count Weighing Mode
6.1 In this mode, scale will weigh goods weight on scale, calculate and display its counts after the piece
weight of goods is obtained
6.2 To make counting function be available, CONFIG-FUNC-COUNT item should be set to YES in
CONFIG menu.
6.3 To enter counting working mode, in normal weighing or percent-weighing mode, long press FUNC
key, WEIGH/PERCEN will be shown, use ACC or PRINT key to select COUNT, then press TARE to
confirm go to parts counting mode. Before new piece weight is got, the last piece weight will be
used.
6.4 In counting working mode, the function of ZERO, TARE, PRINT, HOLD, PRESET TARE, ACC,
SETUP, ON/OFF are available.
6.5 There’re two ways to obtain the piece weight: (1) input piece weight directly, refer operations of
step6.5.1 (2)weigh samples weight which quantity is known, refer operation of step 6.5.2
6.5.1 Input piece weight from keypad: in counting mode, press UNIT key, When InP.PWt is shown, press