CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 25
TARE key to enter input piece weight mode.
6.5.1.1 When UNIT.KG is shown, use PRINT or ACC key to select the unit of piece weight, use TARE key to
confirm and go to next. Press ZERO key to exit getting piece weight mode and back to counting
mode.
6.5.1. When last stored piece weight is shown, use PRINT, ACC, UNIT key to input new piece weight,
press SETUP key more than 3s to input decimal point. Press TARE key to confirm and save it, then
go back to counting mode. If the input piece weight is less than 0.5d, the indicator will display
PWt.Er and go back to counting mode.
6.5.2 Obtain piece weight by weighing samples weight which quantity: in counting mode, press UNIT key,
When InP.PWt is shown, use PRINT or ACC key to select SPL.PWT, press TARE key to weigh
samples (which quantity is known) weight, calculate piece weight. Press ZERO key to exit getting
piece weight mode and back to counting mode.
6.5.2.1 When SPL.Lo is shown, move away any sample on scale and press TARE key to confirm, before
scale is stable, SPL.Lo will be flashed. After it is stable, it will go to next step. Press ZERO key to
exit getting piece weight mode and back to counting mode.
6.5.2.2 When SPL.Hi is shown, put samples (its quantity is known) onto the scale, Press TARE key to
confirm reading weight. Before scale is stable, SPL.Hi will be flashed. After it is stable, it will go to
next step. Press ZERO key to exit getting piece weight mode and back to counting mode.
6.5.2.3 After INP.PCS being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input the
quantity of samples and Press TARE key to confirm. If the calculated piece weight is less than 0.5d,
the indicator will display PWt.Er and go back to counting mode, otherwise, after the reasonable
piece weight being got, the scale will go back to counting mode. The got piece weight can be saved
after the power off and can be used next time.
6.6 Check Counts (counts compare) in Counting mode:
6.6.1 To make counts compare function be available, CONFIG-FUNC-COMPAR item should set to YES,
and high and low limitation of pieces should be set correctly according to following steps:
6.6.2 In counting working mode, Press down DATA key more than 3s to input compare data of high and
low.
6.6.3 After
HIGH being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input high
quantity number and press TARE key to confirm. Annunciator of Hi will be shown in this step. Press
ZERO key to exit getting piece weight mode and back to counting mode.
6.6.4 After Low being shown, 000000 will be displayed, use PRINT, ACC, UNIT key to input low quantity
number and press TARE key to confirm. Annunciator of Lo will be shown in this step. Press ZERO
key to exit getting piece weight mode and back to counting mode.
NOTE: If High number is 0 or is equal or less than low number, the comparison will be disabled.
6.6.5 After a reasonable limitation is set and compare is be active, one of annunciator HI, OK, LO will be
lighted, and the beeper will sound according to its setting in USER-BEEP.