EasyManua.ls Logo

Case 435 - Page 112

Case 435
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DISTRIBUTION SYSTEMS - HIGH-FLOW HYDRAULIC POWER SYSTEM
38. Stop the vacuum pump.
39. Disconnect the vacuum pump from the opening in
the reservoir.
40. Install new hydraulic and hydrostatic lter elements
on the machine.
41. Start the engine. Check for oil leakage around the
new hydra ulic and hydrostatic lters.
42. Stop the eng
ine.
43. Check the level of the oil in the reservoir and add
oil as required. Reservoir - Filling (A.10.A.22 -
F.60.A .10)
1 04/05/2005
A.16.A / 8

Table of Contents

Related product manuals