DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
11. Refer to Hydraulic pump - Flow test (A.10.A.20
- F.40.A.45) If the ow indication for a circ uit was
approximately the same as the ow indication at the
same press ure in Test Number 1 of the Hydraulic
Pump Flow Te st , the circuit is good.
12. If the ow indication for a circuit was more than
3.8 L/min (on e gpm ) less than the ow indication
atthesamepressureinHydraulic pump - Flow
test (A.10.A.20 - F.40.A.45) Test Number 1, there
is leakage in that circuit.