DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
12. If the output at minimum pressure was less than
the specicat ion for Gear Pump Flow to Loader
(Machine in Neutral) refer to Hydraulic pump -
General specication (A.10.A.20 - D.40.A.10),the
problem can be a restriction between the reservoir
and the gear pump, or the problem can be a badly
worn or damaged gear pump.
13. If the output at minimum pressure was more than
the specication refer to Hydraulic pump - General
specication (A.10.A.20 - D.40.A.10), there are no
problems between the re servoir and the gea r pump.
However, the gear pump can be worn or damaged
and still have good ow at minimum pressure.
14. Loss of output at 152 bar (2200 psi) indicates that
the gear pu
mp is worn or damaged. To determine
the efciency of the gear pump, divide the ow
indication from test number 4 by the o w indication
from test n
umber 1. This ans wer m ult iplied by 1 00
is the percent efciency of the gear pump. If the
efciency of the gear pump is less than 75%, repair
or replac
e the gear pump. If the efciency of the
gear pump is more than 75%, the pump is good.