EasyManua.ls Logo

Case CX145C SR - Bringing the Machine up to Operating Temperature

Case CX145C SR
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-OPERATINGINSTRUCTIONS
Bringingthemachineuptooperatingtemperature
NOTICE:Normaloperatingtemperatureofthehydraulicuidisbetween50°C(122.0°F)and80°C(176.0°F),in
themiddleofthetemperatureindicator.
Afterstartingtheengineandbeforeusingthemachine,allowthehydraulicuidtoreachatemperatureof20°C(68.0
°F),asindicatedbytheappearanceofthersttwosegmentsonthehydraulicuidtemperatureindicator.(Referto
page3-19).
Engineautomaticwarm-up
Oncetheenginehasstarted,thewarming-upprocessbeginsautomatically.Atrst,enginespeedisheldatapre-
determined,lowlevel.Asthetemperatureincreases,enginespeedincreasesinproportion.Itispossibletointerrupt
thewarming-upprocessatanytime,simplybymanuallychangingenginespeedorbyoperatingoneofthecontrol
levers.Warming-uptakesapproximately5to10minutes.
Manualenginewarm-up
Withtheenginethrottlebuttonaquarteropen,starttheengineandallowittorunapproximatelyfor5to10minutes.
Whenthecoolanttemperaturereachesthesecondsegment,carryoutthehydraulicuidwarm-upprocedure.
Hydraulicuidwarm-up
1.Turntheenginethrottlebuttontohalf-openposition.Lowerthefunctioncancellationlever.Operatethebucket
controlslowlyuntilthebucketiscompletelyclosed.Operatethearmretractingcontrolslowlyuntilthearmis
completelyretractedandholdthecontrolinthispositionfor30seconds.Duringthistimethetemperatureofthe
hydraulicuidwillincrease.
2.After30seconds,extendthearmcompletelyandholdthecontrolinthispositionafurther30seconds.
3.Continuethearmextendingandretractingprocedureuntilthetemperaturerises(rsttwosegmentsofthetem-
peratureindicator).
4.Operatethetravelandattachmentcontrolsthreeorfourtimestocirculatethehydraulicuid.
4-9

Table of Contents

Related product manuals