6-MAINTENANCE
Cleaningandreplacementofthesuctionlter
1.Releaseallpressureinthehydraulicreservoir.Refer
topage6-37.
2.Cleanthetopofthehydraulicreservoirandcleanthe
suctionltercover.
01268A526
3.Removethecover(1)andO-ring(2)onthetopofthe
suctionlterrodassembly.
4.Removethelter(3)andcleanwithsolvent.Dryit
completelyandcheckitforanydamage.Ifthereis
anydamageonthesurface,replaceitwithanewone.
5.InstallanewO-ring(2),installthelter(3)androd
assembly.
6.Installthecover(1).
7.Checkthelevelofthehydraulicuidandaddmoreif
necessary.See"Fillingthereservoir".
ATTENTION:Installanewinletscreenevery5000hours
ofoperationorwhenthehydraulicuidischanged.
68672B3B7
6-42