6-MAINTENANCE
Bleed
Replace
Grease
Check
Drain
Clean
IntervalPage
no.
MaintenanceActionNo.
of
pts.
6-10
Swingreductiongear
1X
6-39
Suctionlter(NoteW)
1X
6-39
Returncircuitlter(NoteN-P-W)
1X
6-39
Pilotlter(NoteN-W)
1X
Every2000hours
6-73
Airconditioning
1X
6-39
Mainpumpoutputhydraulichoses(NoteQ)
—
X
Every4000hours
6-39
Boom,dipperandbucketcylinderhydraulichoses(NoteQ)
—
X
Every4500hours
6-76
DieselParticulateDiffuser(DPD)(NoteM)
1X
6-39
Inletlter(NoteW)
1X
Every5000hours
6-39
Hydraulicuid(NoteR-W)
1X
3-78
Safetyvalvesontheattachmentcylinders(NoteS)
3X
-
Safetyvalvesonthedozerbladecylinders(standard
machineonly)(NoteS)
2X
6-30
Fuelpre-lter(NoteT)
1X
6-30
Fuellter(NoteT)
1X
6-30
Fuelsupplypumplter(NoteU)
1X
6-56
Tracks(NoteU)
2XX
6-64
Fueltanklter(NoteU)
1X
6-64
Fireextinguisher(NoteV)
1X
6-66
Machinesettings(NoteS)
—
XX
6-66
Machineinspection(NoteU)
—
XX
Asrequired
6-67
Cylindersforleaks(NoteU)
—
X
NoteA:Checkeveryweekandwheneverinstallingthequickcoupler.
NoteB:Tobecheckedevery6monthsbyaspecialist.
NoteC:Ifalltheselinkagepointsarenotequippedwithgenuineparts,thesepointsmustbegreasedevery10hours.
NoteD:Orevery6months.
NoteE:Orwhenthemessage"Airlter"isshownonthemessagescreens.
NoteF:Checkaftertherst50hoursduringtherun-inperiod.
NoteG:Ifalltheselinkagepointsarenotequippedwithgenuineparts,thesepointsmustbegreasedevery50hours.
NoteH:Oreverytwoyearsortwiceayear(autumn/spring)ifantifreezeisused.
NoteJ:Oraftercleaning6times.
NoteK:Oraftertheprimarylterhasbeencleaned3times.
NoteL:Drainaftertherst250hoursduringtherun-inperiod.
NoteM:AskyourCASECONSTRUCTIONDealertocheckthis.
NoteN:Replaceaftertherst250hoursduringtherun-inperiod.
NoteP:Ifbiodegradableuidisused,itisimperativefortheservicingintervaltobereducedto1000hours.
NoteQ:Orevery2years,whichevercomesrst.
6-88